Technical Data
Fiber Optical C37.94 link
- Data speed 2048kbps
- Protocol IEEE C37.94
- Fiber Multi Mode 850nm 50/125um or 62.5/125um, LC-connector (ruggedized) Other fiber optical components available as option
- Optical system budget 13dB in 62.5/um. 9dB in 50/125um fiber
- Typical distance 0 – 2km (3dB system margin for 50/125um and 6dB for 62.5/125um)
Galvanic E1 link
- Data speed 2048kbps
- Protocol G.703, E1
- Connector 120 ohm, RJ45 (BNC connector available)
Galvanic Synchronous Ethernet link
- Data speed 1000 BaseT
- Protocol SyncE according to ITU-T (G.8261, G.8262, G.8264) standardized network with transference of clock signals over Ethernet physical layer
- Connector RJ45 cat 6
- Prerequisites Each network element along a synchronization path must support SyncE
Clock input/output
- Clock frequency out Selectable
- Clock frequency in Selectable
- Connector SMA
Power Supply
- DC 36-75VDC
- AC 85-264VAC, 50−60 Ηz or 120-370VDC.
- AC-connector IEC 320, 3pin, locking IEC
Environmental
- Operating temperature range 25 to +55°C
- Storage temperature range 40 to +85°C
- Relative humidity operating 5 to 95 %
- Relative humidity storage 5 to 95 % non-condensing
CE compliance
- Immunity EN 61000-6-2
- Emission EN 61000-6-4
- LVD EN 50178; RIV = 250 V OVC = III
EMC compliance
- ESD IEC 60255-22-2 Class 3, contact 6kV, air 8kV
- Radiated IEC 60255-22-3 / IEEE/ANSI C37.90.2; 35V/m
- Burst Power IEC 60255-22-1 Class III
- Burst Communication IEC 60255-22-1 Class II; 0,5 kV diff; 1 kV common mode
- Fast transient Power IEC 60255-22-4 Class IV
- Fast transient Communication IEC 60255-22-4 Class II; 1kV
Mechanical compliance
- Vibration IEC 60255-21-1 Class 2
- Shock IEC 60255-21-2 Class 2
- Seismic IEC 60255-21-3 Class 2
Insulation
- Dielectric test IEC 60255-5, 2,0kV 1min
- Impuls voltage test IEC 60255 / EN 50178 5kV / 6kV
- Insulation resistance IEC 60255-5; > 100 Mohm at 500 VDC
Dimensions and Weight
- Height 44 mm (1u)
- Width 444 mm
- Depth 227 mm
- Weight 3 kg